Vulcan I Fire Alarm Control Panel
Ordering Information |
| Part Number |
Description |
VULCAN I FIRE ALARM CONTROL PANEL
The Vulcan I Fire Alarm Control Panel is an F.M. Approved low voltage panel designed
for use in local, auxiliary, remote station or proprietary signaling systems. Some of the
Vulcan I's more prominent features include:
Class A or B operation
Expansion capability up to 13 Class A or 26 Class B zones
Two Class B bell circuits standard; one Class A bell circuit optional
Form C auxiliary alarm and trouble contacts
Lamp Test, Alarm Test, Trouble Silence, Alarm Silence, and Reset Switches
Power, Panel Trouble, Ground Fault LEDs and Alarm and Trouble LEDs for each
zone
Built-in transient protection
|
| 700-026-00 |
Vulcan I Fire Alarm Control Panel, 24 Vdc, One Class A or Two Class B
Zones, 15" x 18" x 3" Surface-Mount Enclosure. Not expandable in this
enclosure. |
| 700-026-01 |
Vulcan I Fire Alarm Control Panel, 24 Vdc, One Class A or Two Class B
Zones, 15" x 14" x 3" Flush-Mount Enclosure. Not expandable in this
enclosure. |
| 700-027-00 |
Vulcan I Fire Alarm Control Panel, 24 Vdc, One Class A or Two Class B
Zones, 28" x 18" x 3.6" Surface-Mount Enclosure. Expandable in this
enclosure to seven Class A or fourteen Class B zones. |
| 700-027-01 |
Vulcan I Fire Alarm Control Panel, 24 Vdc, One Class A or Two Class B
Zones, 28" x 18" x 3.6" Flush-Mount Enclosure. Expandable in this
enclosure to seven Class A or fourteen Class B zones. |
| 700-028-00 |
Vulcan I Fire Alarm Control Panel, 24 Vdc, One Class A or Two Class B
Zones, 40" x 18" x 3.6" Surface-Mount Enclosure. Expandable in this
enclosure to thirteen Class A or twenty-six Class B zones. |
| 700-028-01 |
Vulcan I Fire Alarm Control Panel, 24 Vdc, One Class A or Two Class B
Zones, 40" x 18" x 3.6" Flush-Mount Enclosure. Expandable in this
enclosure to thirteen Class A or twenty-six Class B zones. |
| 176-133-00 |
Zone Expansion Module, 24 Vdc, Two Class A or Four Class B Zones
(or combination) per Module |
| VULCAN I FIRE ALARM CONTROL PANEL OPTIONS
|
| ZONE OPTIONS
|
| 175-047-00 |
Vulcan I Four-Zone Alarm Interface Module, 24 Vdc. For connecting
Two Class A or Four Class B Zone Alarm outputs to the BT2 Building
Transceiver. This Alarm Interface Module allows the user to send in
alarm by zone signals. |
| 790-026-00 |
Vulcan I Zone Expansion Module and Four Zone Alarm/Trouble
Interface Kit, 24 Vdc. For expanding the Vulcan I Fire Alarm Control
Panel by Two Class A or Four Class B Zones and for connecting Two
Class A or Four Class B Zone Alarm and Trouble outputs to the BT2
Building Transceiver. |
| 176-181-01 |
Vulcan I Verification Module Kit. This module allows all zones on Zone
Expansion Modules AFTER the Verification Module to be verified before
they are indicated and reported. |
| BELL CIRCUIT OPTIONS
|
| 790-027-00 |
Vulcan I Class A Bell Circuit Module. This module is mounted in the
Vulcan I Fire Alarm Control Panel. It converts one Class B bell circuit
into a Class A bell circuit. (Two modules required to convert both Class
B bell circuits to Class A circuits.) |
| AUXILIARY SWITCH OPTIONS
|
| 790-022-00 |
Vulcan I Drill Switch. This switch can be held in the DRILL position to
turn on the indicating appliances on the circuit without placing the
control panel in the alarm condition. |
| 790-023-00 |
Vulcan I HVAC Disconnect Switch. This switch is used to prevent
shutdown of air handling systems, exhaust fans, door and elevator
controls, etc. during control panel testing or maintenance. While the
signaling circuit is disconnected, a panel trouble condition exists. |
| 790-024-00 |
Vulcan I BT2 Transmitter Disconnect Switch. This switch is used to
prevent transmission of alarms and troubles to the D-700/D-500 Plus
during control panel testing or maintenance. A panel trouble exists while
the loop is disconnected. |
| POWER SUPPLY OPTIONS
|
| 081-056-00 |
Battery Enclosure Assembly, 18"H x 12"W x 6"D Enclosure; Includes
two 12 Vdc, 26 AH Batteries |
| 404-703-00 |
Remote Power Supply, 6 Amp power supply and battery charger.
Capable of charging 7.7 amp hour batteries (ordered separately). |